ARCAM A2 TECHNICAL DATA
Building tank volume :250x250x400 mm or 350x350x250 mm
Maximum build size: 200x200x350 mm or Ø300×200 mm
Layer thickness :0.05–0.2 mm
EB scan speed :> 1000 m/s
EB positioning accuracy :+/– 0.025 mm
Part Accuracy: +/– 0.3 mm
Calibration :Automatic
Cooling :Automatic start
Power supply :3 x 400 V, 32 A, 7kW
Process computer :PC, XP Professional
CAD interface Standard: STL
Network: Ethernet 10/100